CONVERTER®

MOB Serie

Mobile unit: treating waste directly on site

Transform unsorted waste into a dry, stable product.

Applications
_MILITARY BASES _HUMANITARIAN CAMPS _HOSPITAL CAMPS _RESORTS _CONSTRUCTION SITES _OFFSHORE _ONSHORE _MARKETS _PORTS _CUSTOMS

Open the catalog

TECHNICAL SPECIFICATIONS

MOB20 (200 liters)

Container
20 feet

1 CONVERTER MO200:

RSU / Organic Waste

machine footprint
1900 mm x 1250 mm x 1300 mm height

dry weight
1420 Kg

nominal motor power
60 kW

chamber volume
200 lt

treatment capacity
infected waste: 25 to 40 Kg/h
organic waste: 40 to 60 Kg/h
municipal waste: 60 to 80 Kg/h

Datasheet

MOB20 (400 liters)

Container
20 feet

1 CONVERTER MO400:

RSU / Organic Waste

machine footprint
2240 mm x 1590 mm x 1830 mm height

dry weight
2200 Kg

nominal motor power
77 kW

chamber volume
400 lt

treatment capacity
infected waste: 60 to 80 Kg/h
organic waste: 80 to 120 Kg/h
municipal waste: 100 to 160 Kg/h

Datasheet

MOB40 (400 liters)

Container
hi cube 40 feet

1 Diesel Generator

1 CONVERTER MO400:

RSU / Organic Waste

machine footprint
2240 mm x 1590 mm x 1830 mm height

dry weight
2200 Kg

nominal motor power
77 kW

chamber volume
400 lt

treatment capacity
infected waste: 60 to 80 Kg/h
organic waste: 80 to 120 Kg/h
municipal waste: 100 to 160 Kg/h

Datasheet

MOB40 + (800 liters)

Container
hi cube 40 feet

1 Diesel Generator

2 CONVERTER MO400 (capacity for each):

RSU / Organic Waste

machine footprint
2240 mm x 1590 mm x 1830 mm height

dry weight
2200 Kg

nominal motor power
77 kW

chamber volume
400 lt

treatment capacity
infected waste: 60 to 80 Kg/h
organic waste: 80 to 120 Kg/h
municipal waste: 100 to 160 Kg/h

Datasheet

TECHNOLOGIES COMPARISON

CONVERTER®
(moist heat sterilization)
Autoclave
(hot steam process)
Autoclave
with a shedder
Incinerator
(high-heat process)
Continuous process x x  x  x
Integral shredding x x
Unrecognisable waste x
Volume of waste reduction x
Mass of waste reduction x x
Installation requirements Low High High High
Complexity of the installation Low Intermediate High High
Possibility of installation “in situ” x
Technology approval and recognition by countries all over the world High Intermediate High Low
Level of sterelization High Intermediate High High
Odours Low High Intermediate Intermediate
Level of noise Low Intermediate Intermediate High
Treatment of pathological and anatomical waste x

 

CONVERTER®
(moist heat sterilization)
Autoclave
(hot steam process)
Autoclave
with a shedder
Incinerator
(high-heat process)
ROI High Low Low Low
Investment costs High Low Intermediate High
Operating costs Low High High High
Maintenance costs Low High High High
Labour costs Low High High High

 

CONVERTER®
(moist heat sterilization)
Autoclave
(hot steam process)
Autoclave
with a shedder
Incinerator
(high-heat process)
Impact on the environment No Intermediate Intermediate  High
Treated waste recyclable x x x
No contaminated rejection (such as water, steam) x x x
CONVERTER®
(moist heat sterilization)
Autoclave
(hot steam process)
Autoclave
with a shedder
Incinerator
(high-heat process)
No risk related to pressurized vessel x x x
Risk for workforce/personnel health
(no risk of toxic contaminants released
into the air or the treated waste)
No No Intermediate High